Systems Security Certified Practitioner – SSCP – Question0529

Recovery Site Strategies for the technology environment depend on how much downtime an organization can tolerate before the recovery must be completed. What would you call a strategy where the alternate site is internal, standby ready, with all the technology and equipment necessary to run the applications?

A.
External Hot site
B. Warm Site
C. Internal Hot Site
D. Dual Data Center

Correct Answer: C

Explanation:

Internal Hot Site—This site is standby ready with all the technology and equipment necessary to run the applications positioned there. The planner will be able to effectively restart an application in a hot site recovery without having to perform any bare metal recovery of servers. If this is an internal solution, then often the organization will run non-time sensitive processes there such as development or test environments, which will be pushed aside for recovery of production when needed. When employing this strategy, it is important that the two environments be kept as close to identical as possible to avoid problems with O/S levels, hardware differences, capacity differences, etc., from preventing or delaying recovery. Recovery Site Strategies Depending on how much downtime an organization has before the technology recovery must be complete, recovery strategies selected for the technology environment could be any one of the following: Dual Data Center—This strategy is employed for applications, which cannot accept any downtime without negatively impacting the organization. The applications are split between two geographically dispersed data centers and either load balanced between the two centers or hot swapped between the two centers. The surviving data center must have enough head room to carry the full production load in either case.
External Hot Site—This strategy has equipment on the floor waiting, but the environment must be rebuilt for the recovery. These are services contracted through a recovery service provider. Again, it is important that the two environments be kept as close to identical as possible to avoid problems with O/S levels, hardware differences, capacity differences, etc., from preventing or delaying recovery. Hot site vendors tend to have the most commonly used hardware and software products to attract the largest number of customers to utilize the site. Unique equipment or software would generally need to be provided by the organization either at time of disaster or stored there ahead of time. Warm Site—A leased or rented facility that is usually partially configured with some equipment, but not the actual computers. It will generally have all the cooling, cabling, and networks in place to accommodate the recovery but the actual servers, mainframe, etc., equipment are delivered to the site at time of disaster. Cold Site—A cold site is a shell or empty data center space with no technology on the floor. All technology must be purchased or acquired at the time of disaster.
Reference(s) used for this question: Hernandez CISSP, Steven (2012-12-21). Official (ISC)2 Guide to the CISSP CBK, Third Edition ((ISC)2 Press) (Kindle Locations 21265-21291). Auerbach Publications. Kindle Edition.